Add to Cart
ELG-240-48A Constant Current Taiwan Mean Well Meanwell 240W 5.0A Power Supply
Detailes:
MODEL | ELG-240-24 | ELG-240-36 | ELG-240-42 | ELG-240-48 | |
OUTPUT | DC VOLTAGE | 24V | 36V | 42V | 48V |
CONSTANT CURRENT REGION | 12 ~ 24V | 18 ~ 36V | 21 ~ 42V | 24 ~ 48V | |
RATED CURRENT | 10A | 6.66A | 5.71A | 5.0A | |
RATED POWER | 200VAC ~ 305VAC | ||||
240W | 239.76W | 239.82W | 240W | ||
100VAC ~ 180VAC | |||||
180W | 180W | 179.76W | 180W | ||
RIPPLE & NOISE (max.) | 200mVp-p | 250mVp-p | 250mVp-p | 250mVp-p | |
VOLTAGE ADJ. RANGE | Adjustable for A-Type only (via the built-in potentiometer) | ||||
22.4 ~ 25.6V | 33.5 ~ 38.5V | 39 ~ 45V | 44.8 ~ 51.2V | ||
CURRENT ADJ. RANGE | Adjustable for A-Type only (via the built-in potentiometer) | ||||
5 ~ 10A | 3.33 ~ 6.66A | 2.86 ~ 5.71A | 2.5 ~ 5A | ||
VOLTAGE TOLERANCE | ±2.0% | ±2.0% | ±2.0% | ±2.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 500ms, 100ms/230VAC, 1000ms, 100ms/115VAC | ||||
HOLD UP TIME (Typ.) | 10ms/ 230VAC 10ms/ 115VAC | ||||
INPUT | VOLTAGE RANGE | 100 ~ 305VAC 142 ~ 431VDC (Please refer to "STATIC CHARACTERISTIC" section) | |||
FREQUENCY RANGE | 47 ~ 63Hz | ||||
POWER FACTOR | PF>=0.97/115VAC,PF>=0.95/230VAC PF>=0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve) | ||||
TOTAL HARMONIC DISTORTION | THD< 20% when output loading>=50% at 115VAC , 230VAC input ; and output loading>=75% at 277VAC input (Please refer to “TOTAL HARMONIC DISTORTION(THD)” section) | ||||
EFFICIENCY (Typ.) | 92% | 92% | 92.5% | 93% | |
AC CURRENT | 2.2A / 115VAC 1.5A / 230VAC 1.2A/277VAC | ||||
INRUSH CURRENT (Typ.) | COLD START 60A(twidth=510μs measured at 50% Ipeak) at 230VAC; Per NEMA 410 | ||||
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC | ||||
LEAKAGE CURRENT | <0.75mA / 277VAC | ||||
NO LOAD / STANDBY POWER CONSUMPTION | No load power consumption <0.5W for Blank / A / Dx / D-Type Standby power consumption <0.5W for B / DA-Type | ||||
PROTECTION | OVER CURRENT | 95 ~ 108% | |||
Constant current limiting, recovers automatically after fault condition is removed | |||||
SHORT CIRCUIT | Hiccup mode, recovers automatically after fault condition is removed | ||||
OVER VOLTAGE | 27 ~ 34V | 42 ~ 49V | 47 ~ 54V | 54 ~ 63V | |
Protection type : Shut down o/p voltage, re-power on to recovery | |||||
OVER TEMPERATURE | Shut down o/p voltage, re-power on to recovery | ||||
ENVIRONMENT | WORKING TEMP. | Tcase=-40 ~ +90°C(Refer to "Derating Curve") | |||
MAX. CASE TEMP. | Tcase=+90°C | ||||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | ||||
STORAGE TEMP., HUMIDITY | ’-40 ~ +90°C,10~95% RH | ||||
TEMP. COEFFICIENT | ±0.03%/°C (0 ~ 50°C) | ||||
VIBRATION | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes | ||||
SAFETY & EMC | SAFETY STANDARDS | U8750(type”HL”), CSA C22.2 No. 250.13-12; ENEC EN61347-1, EN61347-2-13 independent, EN62384;GB19510.14, GB19510.14,B19510.1; IP65 or IP67 approved | |||
DALI STANDARDS | Compliy with IEC62386-101, 102, 207 for DA-Type only | ||||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC | ||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH | ||||
EMC EMISSION | Compliance to EN55015,EN61000-3-2 Class C (>=50% loading) ; EN61000-3-3; GB17625,GB17743 | ||||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level (surge immunity Line-Earth 6KV, Line-Line 4KV) | ||||
OTHERS | MTBF | 826.7K hrs min. Telcordia SR-332 (Bellcore) ; 200.8Khrs min. MIL-HDBK-217F (25°C) | |||
DIMENSION | 244*71**37.5mm (L*W*H) | ||||
PACKING | 1.05Kg 12pcs/13.6kg/0.72CUFT |
Features:
Applications